Pharmacognosy Magazine

ORIGINAL ARTICLE
Year
: 2012  |  Volume : 8  |  Issue : 31  |  Page : 231--236

Simultaneous determination of ten bioactive compaounds from the roots of Cynanchum paniculatum by using high performance liquid chromatography coupled-diode array detector


Jin Bae Weon1, Bohyoung Lee1, Bo-Ra Yun1, Jiwoo Lee1, Choong Je Ma2 
1 Department of Biomaterials Engineering, Division of Bioscience and Biotechnology, Kangwon National University, Chuncheon 200-701, Korea
2 Department of Biomaterials Engineering, Division of Bioscience and Biotechnology, Kangwon National University, Chuncheon 200-701; Research Institute of Biotechnology, Kangwon National University, Chuncheon 200-701, Korea

Correspondence Address:
Choong Je Ma
Department of Biomaterials Engineering, Division of Biotechnology and Bioengineering, Kangwon National University, Hyoja-2 Dong, Chuncheon 200-701
Korea

Background: Cynanchum paniculatum Kitagawa belongs to Asclepiadaceae and was used in traditional medicine to invigorate blood, alleviate edema, relieve pain, and relieve toxicity for a long time. Objective: A novel and reliable high performance liquid chromatography coupled with diode array detector method has been established for simultaneous determination of 10 bioactive compounds isolated from Cynanchum paniculatum Kitagawa, one of the herbal medicines. Materials and Methods: The chromatography analysis was performed on a SHISEIDO C 18 column (S-5 μm, 4.6 mm I.D. × 250 mm) at 35 o C with a gradient elution of acetonitrile and water at a flow rate of 1ml/min and UV detection at 210, 230, and 280 nm. Results: The method was validated for linearity, precision, and accuracy. All calibration curves showed good linear regression (r2 > 0.9996). Limits of detection (LOD) and limits of quantification (LOQ) fell in the ranges 0.01 - 0.28 μg/ml and 0.04 - 0.83 μg/ml, respectively. The relative standard deviation (RSD) of the intra- and inter- day test, precision test were within 1.92% and 2.43%, respectively. The mean recovery of all ranged from 92.82 to 107.96% with RSD values 0.12 - 2.18%. Conclusion: The results of validation appeared that this established method was very accurate and stabilized for the quantification of 10 bioactive compounds isolated from C. paniculatum.


How to cite this article:
Weon JB, Lee B, Yun BR, Lee J, Ma CJ. Simultaneous determination of ten bioactive compaounds from the roots of Cynanchum paniculatum by using high performance liquid chromatography coupled-diode array detector.Phcog Mag 2012;8:231-236


How to cite this URL:
Weon JB, Lee B, Yun BR, Lee J, Ma CJ. Simultaneous determination of ten bioactive compaounds from the roots of Cynanchum paniculatum by using high performance liquid chromatography coupled-diode array detector. Phcog Mag [serial online] 2012 [cited 2019 Aug 19 ];8:231-236
Available from: http://www.phcog.com/article.asp?issn=0973-1296;year=2012;volume=8;issue=31;spage=231;epage=236;aulast=Weon;type=0