Home | About PM | Editorial board | Search | Ahead of print | Current Issue | Archives | Instructions | Subscribe | Advertise | Contact us |  Login 
Pharmacognosy Magazine
Search Article 
  
Advanced search 
 
ORIGINAL ARTICLE
Year : 2015  |  Volume : 11  |  Issue : 43  |  Page : 555-561

Simultaneous determination of nine marker compounds in the traditional Korean medicine, Dangguisu san by high performance liquid chromatography


Herbal Medicine Formulation Research Group, Herbal Medicine Research Division, Institute, 1672 Yuseongdae ro, Yuseong gu, Daejeon, 305 811, Republic of, Korea

Correspondence Address:
Hyeun-Kyoo Shin
Herbal Medicine Formulation Research Group, Herbal Medicine Research Division, Institute, 1672 Yuseongdae ro, Yuseong gu, Daejeon, 305 811, Republic of
Korea
Login to access the Email id

Source of Support: This research was supported by a grant (no. K14030) from the Korea Institute of Oriental Medicine, Conflict of Interest: None declared.


DOI: 10.4103/0973-1296.160457

Rights and Permissions

Background: Dangguisu-san (DGSS) has been widely used to treat ecchymosis, blood stagnation and pain resulting from physical shock in Korea. Objective: A high performance liquid chromatography–photodiode array detection (HPLC–PDA) method for simultaneous analysis of nine components, albiflorin (1), paeoniflorin (2), liquiritin (3), nodakenin (4), coumarin (5), liquiritigenin (6), cinnamic acid (7), cinnamaldehyde (8), and glycyrrhizin (9) in DGSS extract has been developed for the first time. Materials and Methods: The analytical column for separation of the nine constituents used a Gemini C18 column kept at 40°C by the gradient elution with 1.0% (v/v) acetic acid in water and 1.0% (v/v) acetic acid in acetonitrile as mobile phase. The flow rate was 1.0 mL/min and the injection volume was 10 μL. Results: Calibration curves of all compounds showed good linearity (r2 ≥ 0.9999) within the test ranges. The limits of detection and quantification for all analytes were 0.01–0.27 μg/mL and 0.04–0.89 μg/mL, respectively. All recoveries of the nine marker compounds were 96.62–102.47% with relative standard deviations (RSD) <1.72%. The RSDs of intra day and inter day precision were <1.32% and 1.61%, respectively. The amounts of the nine marker components ranged from 0.10 mg/g to 13.71 mg/g. Conclusion: The developed and validated HPLC–PDA method may help for the quality control of DGSS.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed1475    
    Printed46    
    Emailed0    
    PDF Downloaded15    
    Comments [Add]    
    Cited by others 1    

Recommend this journal